Hoist brand                  : L8304 Italkrane hoist

Problem                       : Hoist movement intermittent (on/off)

Causes                         : Supply cable at control pendant has broken

Solution                        :   - Change a new wire for supply cable at control pendant and  
       main supply.
                                        - Check the cable status have 12 cable but only used 8 cable, and
                                           balance 4 cables. We use only one cable from the balance so    
                                           total left 3 cables.
- We use the balance cable to loop and rewiring back the
   damage cable. So the problem being solve by only using the
   balance cable. Also rewiring back at the pendant control and
   the junction box
           
           
Please refer service report for additional information (recommended parts)

- Chain rubber buffer at bottom block need to be change for safety purpose due to already exhausted.